Yamaha DME User Manual

Page 108

Advertising
background image

Chapter 3 Main Panel Window

DME Designer Owner’s Manual

108

■ [DME]

From the list, select the DME where you will be making settings.

■ Configuration

The current configuration name will be displayed.

■ GPI IN

The DME64N has 16 GPI IN channels, and the DME24N/DME Satellite has 8 GPI IN ports.
These settings determine which DME parameters will be controlled by input received at each
individual GPI IN port. The port numbers are shown in the leftmost column.

[Function]

Specifies the function to be controlled by GPI input. Click to see a list from which you can choose
the function to be assigned to the corresponding GPI IN port.
The ten available functions are: [No Assign], [Parameter Value Edit], [Direct Parameter Value],
[Scene Change], [Scene Increment], [Scene Decrement], [Mute], [GPI Lock], [Time Adjustment],
[Play Wav File].
The [Parameter], [Min], [Max], and [Terminal] items will change according to the selected function.

• [No Assign]

No function assigned. This is the default setting.
Select [No Assign] to clear an assigned function.
The [Parameter], [Min], [Max], and [Terminal] items are not available.

• [Parameter Value Edit]

Allows component parameters to be changed via GPI input.
In this case [Parameter] is used to select the parameter to be controlled.
[Min] and [Max] specify the range over which the parameter can be changed.
[Terminal] determines how the GPI input voltage will affect the specified parameter.

and

specify continuous control of continuously-variable parameters from an external

fader, knob, or similar device.

and

specify on/off control of 2-state parameters via an external switching device.

NOTE

Components for user modules are also listed in a hierarchal display, but if user module security is enabled, the
components are not displayed. However, parameters displayed in the user module editor are displayed here.

Advertising