Yamaha DME User Manual

Page 408

Advertising
background image

Chapter 6 Component Guide

DME Designer Owner’s Manual

408

7

LPF

Frequency

20 Hz to 20 kHz

Sets the LPF cutoff frequency.

8

Type

Thru
6 dB/Oct
12 dB/Oct AdjustGc
12 dB/Oct Butrwrth
12 dB/Oct Bessel
12 dB/Oct Linkwitz
18 dB/Oct AdjustGc
18 dB/Oct Butrwrth
18 dB/Oct Bessel
24 dB/Oct AdjustGc
24 dB/Oct Butrwrth
24 dB/Oct Bessel
24 dB/Oct Linkwitz
36 dB/Oct AdjustGc
36 dB/Oct Butrwrth
36 dB/Oct Bessel
48 dB/Oct AdjustGc
48 dB/Oct Butrwrth
48 dB/Oct Bessel
48 dB/Oct Linkwitz

Sets the attenuation for each octave and the
filter type.
[THRU] turns off the filter.

9

Gc

-6 dB to +6 dB

When [AdjustGc] (Adjustable Gc) is selected
for [Type], this sets the gain for the cutoff
frequency.

)

Bypass

ON/OFF

Turns bypass ON.

!

Output

Level

-

∞ to ±0 dB

Sets the output signal level.

Section

Parameter

Setting Range

Function