Yamaha DME User Manual

Page 167

Advertising
background image

Chapter 3 Main Panel Window

DME Designer Owner’s Manual

167

MIDI CH

Sets the MIDI channel. This number is also used as the Parameter Change Device ID.

• [Tx]
Select the MIDI transmit channel from the list.

• [Rx]
Select the MIDI receive channel from the list.

Program Change/Control Change/Parameter Change

Sets transmit (Tx), receive (Rx), OMNI, and Echo for program change/control change/parameter
change. When ON, clicking turns this OFF. When OFF, clicking turns this ON. When OMNI is [ON]
channel messages are received regardless of the receive channel setting. When ECHO is [ON] the
input data is “echoed” (re-transmitted) via the output port that corresponds to the input port via
which it was received.
Program change, control change, and parameter change details can be set up via the “MIDI”
window [Program Change], [Control Change], and [Parameter Change] tabs, respectively.

GPI Tab

Calibrates the input voltage detection range for a DME unit GPI terminal.

[ALL] Checkbox

Automatically checks all channel checkboxes.

[Ch] Checkbox

These checkboxes specify the channels to be calibrated.

Calibration Information

Displays the input voltage in real time.

[Reset] Button

Resets the calibration of checked channels.

[Max] Button

Sets the current input voltage as the maximum input voltage for checked channels.
The specified maximum voltage is indicated by a red bar.

[Min] Button

Sets the current input voltage as the minimum input voltage for checked channels.
The specified minimum voltage is indicated by a blue bar.