[Control Change] Tab

Assigns components to control change for each DME. You can change DME parameters by sending
control change messages from external equipment.
You can assign to control change numbers 1-31, 33-95, and 102-119.

Control Change List

The control change numbers and current settings are displayed in the list in the center.

No.

Displays the control change numbers.

Component

Displays the assigned components. Control changes that have no component assigned to them
are blank. If you click here, a list will be displayed. Usable components are on the list. Click the
component name to select it.

NOTE

Because control change numbers 0 and 32 are used for bank select MSB, numbers 96-101 are RPN/NRPN related, and
120-127 are used for mode messages, they cannot be used for component assignment.

NOTE

If user module security is enabled, the components are not displayed. However, parameters displayed in the user
module editor are displayed here.