Chapter 3 Main Panel Window

DME Designer Owner’s Manual

114

• [Time Adjustment]

GPI input can be used to adjust the DME internal clock as follows:

[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.

and

specify continuous control of continuously-variable parameters from an external

fader, knob, or similar device.

and

specify on/off control of 2-state parameters via an external switching device.

The internal clock time will be adjusted each time the voltage applied to GPI IN rises from below to
above the median voltage.*

The internal clock time will be adjusted each time the voltage applied to GPI IN drops from above to
below the median voltage.*

Same as

.

Same as

.

Internal clock time

Time after adjustment

0~14 seconds

Returned to 0 seconds

15~29 seconds

Advanced to 30 seconds

30~44 seconds

Returned to 30 seconds

45~59 seconds

Advanced to 0 seconds

Max. voltage applied to GPI IN

Min. voltage applied to GPI IN

Median voltage

Trigger

Max. voltage applied to GPI IN

Min. voltage applied to GPI IN

Median voltage

Trigger