Daily weight daily feedings fcr – YSI 5200A User Manual

Page 77

Advertising
background image

YSI 5200A
152

YSI 5200A
153

Notes:

If a timed feed cycle includes feed times that cross midnight, the feed

-

cycle ends prior to 11:59 pm (23:59) of the enabled day when crossing

midnight to a disabled day. Feeding(s) will resume on next enabled day.

Example - if Tues through Sat are enabled days and the start time is con-

figured for 10:00 pm (23:00) and the end time is configured for 01:00.

On a Saturday, the feed cycle would start at 10:00 pm (23:00). The last

feed occurs by 11:59 pm (23:59) on Saturday since Sunday is a disabled

day. The next feed occurs at 12:00 am (0:00) on Tuesday. This feed cycle

would end at 01:00 on Tuesday. No feeding occurs Monday, because

Monday is a disabled day.

The Feed timer will not operate properly if the start date is set prior to

-

January 1, 2007.

Daily Weight

Menus →Timers→Feed Smart Timer→Feeder→Daily Weight

The daily feed amount is the total weight of food that will be dispensed over the

feeding cycle. The value is user selectable from 1 to 100000. The Feed Timer system

divides the total daily feed amount by the number of daily feedings and uses the

calibration/test data to determine feed duration and interval times.

Daily Feedings

Menus →Timers→Feed Smart Timer→Feeder→Daily Feedings

Configure the number of feedings to occur in feed cycle. The value is user select-

able 1–255.

Configuring the 5200A

FCR

Menus →Timers→Feed Smart Timer→Feeder→FCR

The optional FCR (feed conversion ratio) feature automatically increases the amount

of food dispensed over a feed cycle. The increase in the amount of food is based on

the user configured increase in biomass over a 24 hour period. Biomass and daily

(feed) weight amounts are adjusted by the 5200A prior to the 1st feed “on” time of

a scheduled feed cycle occurring after midnight.

Notes:

With FCR enabled and properly configured an event occurs when the

-

5200A time crosses midnight. See below.

Biomass

Menus →Timers→Feed Smart Timer→Feeder→FCR→Biomass

Enter the total weight of livestock being fed at the time FCR is enabled. The value

is user selectable 1 to 100000.

Feed % (of) Biomass

Menus →Timers→Feed Smart Timer→Feeder→FCR→Feed % Biomass

Enter the percentage of the total livestock weight (biomass) that will be used to

determine the daily feed weight. The value is user selectable 0.0–99.9%.

Daily (Feed) Weight

Menus →Timers→Feed Smart Timer→Feeder→FCR→Daily Weight

Configure the initial daily feed weight by multiplying the biomass amount by the Feed

% Biomass percentage (the 5200A will not calculate the initial amount). Example—if

the biomass is 1000 and the feed % biomass is 3%, then the initial daily feed weight

amount is 30. On each following day, the 5200A will use the biomass value along

with the feed % biomass to calculate the new daily feed weight amount.

Configuring the 5200A

Advertising