YSI 5200A
154

YSI 5200A
155

Note:

The initial daily weight value must be calculated as described above.

-

Configuring an invalid initial daily weight will result in incorrect biomass

and daily weight calculations when the 5200A crosses midnight.

FCR Factor

Menus →Timers→Feed Smart Timer→Feeder→FCR→FCR Factor

Enter the ratio of the amount of food required versus the corresponding increase

in fish weight (biomass). This value is used to automatically increase the biomass

amount—as shown in the example below.

Sensors

Menus →Timers→Feed Smart Timer→Feeder→Sensors

→Disabled/Enabled

→DO Low/High/DO % Change

→pH Low/High/pH % Change

→Temp Low/High/Temp % Change

Changes in water conditions affect the amount of food fish eat which in turn affects

fish growth. With the sensor feature enabled, the feed timer system will verify that

DO, temperature, and pH values are within user configured ranges. This verification

is done immediately prior to starting each feed duration in a feed cycle. If values

are reported that fall outside the acceptable configured ranges, the feed timer relay

energizes for a shorter period (user configured percentage) thereby reducing the

amount of food that is dispensed. Feed timer sensor ranges are independent of

sensor setup configuration ranges. For timed feed cycles, the feed interval for the

entire feed cycle is determined by duration of the first feed.

Configuring the 5200A

Example - The feed timer is configured as follows: sensor temperature low value

is 25.1oC, feed timer temperature change is 9%, timed feed mode, six feeds, daily

weight 2 units start time 8A, end time 9A, six 9.999 second feeds of .3333 units

each to occur at 9 minute 50 second intervals without sensor reduction. Prior

to 8A feed cycle, the start temperature value is reading 24.9oC. Feed duration of

9.999 seconds will be reduced by approximately 1 second (9%) because of the “out

of range” temperature value.

DO Low/pH Low/Temp Low

Enter the lower limit of the sensor range where no feed reduction will take place.

DO High/pH High/Temp High

Enter the high limit of the sensor range where no feed reduction will take place.

DO Change/pH Change/Temp Change

Enter the percent reduction in feed weight that will occur for “out of range” enabled

feed timer sensors. Results from all out of range sensors are added. To disable a

sensor value from affecting feed duration configure 0.0% as the % change for that

sensor.

Calibrate

Menus →Timers→Feed Smart Timer→Feeder→Calibrate

Calibrating the feeder is essential for proper operation of the feed timer system.

Feed timer calibration is required to establish the amount of food dispensed over

a certain period of time. The 5200A will base feed cycle duration times on the last

saved calibration value.

Configuring the 5200A