4 push & hold mode, Pl c – IAI America ACON-CG User Manual

Page 108

Advertising
background image

94

7. Operation <Practical Steps>

7.4 Push & Hold Mode

Example of use in operation) The actuator is caused to move back and forth in the push & hold mode and positioning

mode. The position 280 mm from the home is set as position 1, and the position 40 mm
from the home is set as position 2.
Movement to position 1 is performed in the push & hold mode (the actuator is caused to
contact the work part and push it in the counter-motor direction). The maximum push
amount at position 1 is set as 15 mm, and the current-limiting value during the push &
hold operation by the stepper motor is set as 50%. Movement to position 2 is performed
in the positioning mode. The travel speed to position 1 is set as 200 mm/sec, and that to
position 2 is set as 100 mm/sec.

Controller

[13] [10] [5] [2]

[1]

[9]

[7]

[15]

[14] [11] [6] [3]

[16] [12] [8] [4]

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[9]

[10]

[11]

[12]

[13]

[14]

[15]

[16]

P

L

C

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

Command position 16

Command position 32

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Completed position 16

Completed position 32

Position complete

Moving

Category

Input

Output

Reference flow

Select/enter command position 1.

Start input ON

Movement to position 1 starts.

Completed position OFF

Position complete output OFF

Moving output ON

Start input OFF

Position complete output ON

Completed position 1 is output.

Moving output OFF

Select/enter command position 2.

Start input ON

Movement to position 2 starts.

Completed position OFF

Position complete output OFF

Moving output ON

Start input OFF

Completed position 2 is output.

Moving output OFF

Movement to position 2 completes.

Move at slow speed after passing position 1.

Load is pushed. Stepper motor current
rises to the current-limiting value.

Position complete output turns ON
0.1 mm before position 2.

Advertising
This manual is related to the following products: