32 4. w iring – IAI America ACON-CG User Manual

Page 46

Advertising
background image

32

4. W

iring

Controller

0 V (NPN
specification)
24 V (PNP
specification)

24 V (NPN
specification)
0 V (PNP
specification)

24-VDC power for input/output
signals

‚

For details on I/O signal connection, refer to

4.3, “Connecting the I/O Cables.”

‚

Refer to the operation manual of each
network and the operation manual of the PLC
master unit for how to wire communication
cables of the network connection
specifications.

Input

Output

Motor extension cable

Encoder extension cable

Blue

Orange

Gray

Red

Black

Yellow

Pink

Purple

Orange/White

Green/White

Blue/Red

Brown

Green

Connected to teaching
pendant or PC

Input power
supply
24 VDC

Motor drive-
power cutoff
circuit

Actuator

Mot

o

r

Encoder

Holding brake

Terminal block

Red

White

Black

Connection

detection circuit

Brake release switch

Tighten together with the
mounting screw.

Home check

sensor

Load

Load

I/O flat cable

4.2 Safety Category Type (External Drive-power Cutoff Relay) (ACON-CG)

4.2.1 External

Connection

Diagram

An example of standard wiring is shown below.
(Note) The encoder cable shown in the example is the standard cable.

As for the robot cable or the cable for the dedicated controller for the high-thrust type, refer to 4.4.2,
“Encoder Extension Cable.”

Advertising