Code Error

name

Cause/Action

0F4 Unmatched PCB

This controller uses a different motor drive circuit depending on the motor
capacity, and thus adopts a different printed circuit board (PCB)
appropriate for each motor capacity.
For this reason, whether the motor type set by the applicable
manufacturer’s parameter matches the board is checked in the initialization
process after startup.
This error indicates that the two do not match.
Cause: The parameter was not entered correctly or the correct board was

not assembled.

Action: Should this error occur, please contact IAI.

0F5 Nonvolatile

memory

write verification error

When data has been written to the nonvolatile memory, the written data is
read again to check (verify) if it matches the original data.
This error indicates that the two data do not match.
Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(The nominal rewrite limit of the nonvolatile memory is around
100,000 times.)

Action: If the alarm generates again after reconnecting the power, please

contact IAI.

0F6 Nonvolatile

memory

write timeout

This error indicates that response is not received within the specified time
after data was written to the nonvolatile memory.
Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(The nominal rewrite limit of the nonvolatile memory is around
100,000 times.)

Action: If the alarm generates again after reconnecting the power, please

contact IAI.

0F8 Damaged

nonvolatile

memory

Abnormal data was detected during the nonvolatile memory check after
starting.
Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(The nominal rewrite limit of the nonvolatile memory is around
100,000 times.)

Action: If the alarm generates again after reconnecting the power, please

contact IAI.

0FA CPU error

The CPU is not operating properly.
Cause: [1] Faulty

CPU

[2] Malfunction due to noise

Action: If the alarm generates again after reconnecting the power, please

contact IAI.