7. Operation <Practical Steps>

T1:

6 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)

Caution: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.
Always turn OFF the start signal after confirming that the start signal is currently ON and the
position complete output has turned OFF.

Example of other zone output)

Zone output at 120 or more

Zone output at 40 or less

Zone boundary+

Maximum stroke length

Zone boundary+

40

Zone boundary–

120

Zone boundary–

0

Zone

Zone

120

40

T

1

Command position

Start

Position complete

Completed position

Zone

Moving

Actuator movement

Speed

Note

0 mm

40 mm

120 mm

150 mm