IAI America ACON-CG User Manual

Page 78

Advertising
background image

64

5. I/O Signal Control and Signal Functions

„ Emergency stop (*EMGS)

This signal remains ON while the controller is normal, and will turn OFF if the emergency stop circuit is cut off.
Program the PLC so that it will monitor this signal and implement appropriate safety measures for the entire
system if the signal turns OFF.

„ Output Signal Changes in Each Mode

Mode classification

MOVE

PEND

SV

HEND

PM1 ~

PM256

Actuator is stopped with the servo ON after the power
was input

OFF ON ON OFF OFF

Home return is in progress following an input of the
home return signal

ON OFF ON OFF OFF

Home return has completed following an input of the
home return signal

OFF ON ON ON OFF

Actuator is moving in the positioning/push & hold mode

ON

OFF

ON

ON

OFF

Actuator is paused in the positioning/push & hold mode

OFF

OFF

ON

ON

OFF

Positioning has completed in the positioning mode

OFF

ON

ON

ON

ON

Actuator has stopped after contacting the work part in
the push & hold mode

OFF ON ON ON ON

Actuator has stopped after missing the work part (no
work part) in the push & hold mode

OFF OFF ON ON ON

Actuator is stopped with the servo ON in the teaching
mode

OFF ON

ON

Actuator is jogging in the teaching mode

ON

ON

ON

Actuator is being moved by hand with the servo OFF in
the teaching mode

OFF

OFF ON

Servo is OFF after home return

OFF

OFF

OFF

ON

OFF

Emergency stop has been actuated after home return

OFF

OFF

OFF

ON

(Note) Determine whether the actuator has stopped after contacting the work part or missing the work part from

the signal statuses of MOVE, PEND and PM1 to PM256.