5. I/O Signal Control and Signal Functions

z PIO pattern = 4 [Solenoid valve mode 1 (7-point type)]

Category Signal

name

Signal

abbreviation

Function overview

Direct position
command 0

ST0

The actuator will start moving to position No. 0 at a rise edge
of this signal.

Direct position
command 1

ST1

The actuator will start moving to position No. 1 at a rise edge
of this signal.

Direct position
command 2

ST2

The actuator will start moving to position No. 2 at a rise edge
of this signal.

Direct position
command 3

ST3

The actuator will start moving to position No. 3 at a rise edge
of this signal.

Direct position
command 4

ST4

The actuator will start moving to position No. 4 at a rise edge
of this signal.

Direct position
command 5

ST5

The actuator will start moving to position No. 5 at a rise edge
of this signal.

Direct position
command 6

ST6

The actuator will start moving to position No. 6 at a rise edge
of this signal.

Brake release

BKRL

This signal is used on an actuator equipped with a brake to
forcibly release the brake.

Operating mode

RMOD

This signal switches the operating mode between AUTO and
MANU.

Home return

HOME

Home return operation is started at a rise edge of this signal.

*Pause *STP

ON: Actuator can be moved, OFF: Actuator decelerates to a
stop

Alarm reset

RES

An alarm is reset at a rise edge of this signal.

Input

Servo ON

SON

The servo remains ON while this signal is ON.
The servo remains OFF while this signal is OFF.

Movement complete 0 PE0

This signal will turn ON when the actuator completes moving
to position No. 0.

Movement complete 1 PE1

This signal will turn ON when the actuator completes moving
to position No. 1.

Movement complete 2 PE2

This signal will turn ON when the actuator completes moving
to position No. 2.

Movement complete 3 PE3

This signal will turn ON when the actuator completes moving
to position No. 3.

Movement complete 4 PE4

This signal will turn ON when the actuator completes moving
to position No. 4.

Movement complete 5 PE5

This signal will turn ON when the actuator completes moving
to position No. 5.

Movement complete 6 PE6

This signal will turn ON when the actuator completes moving
to position No. 6.

Zone ZONE1

This signal becomes effective after home return. It will turn ON
when the current actuator position enters the range set by the
parameters and remain ON until the actuator exits the range.

Position zone

PZONE

This signal becomes effective after a position movement
command is input. It will turn ON when the current actuator
position enters the range specified in the position table and
remain ON until the actuator exits the range.

Operating mode status RMDS

This signal will remain OFF during the AUTO mode, and ON
during the MANU mode.

Home return
completion

HEND

This signal is OFF immediately after the power is input, and
turns ON when home return has completed.

Position complete

PEND

This signal is used to determine if the controller is ready
following the power on.
The controller is ready to perform operation if an emergency
stop is not actuated, motor drive power is not cut off (= the
servo is on) and the pause signal is input.

Ready SV

This signal is always output once the servo is turned ON and
the controller is ready to operate.

*Emergency stop

*EMGS

OFF: Emergency stop has been actuated

Output

*Alarm *ALM

This signal remains ON in normal conditions of use and turns
OFF when an alarm generates.