7. Operation <Practical Steps>

Position table (Field(s) within thick line must be entered.)

No.

Position

[mm]

Speed

[mm/s]

Acceleration

[G]

Deceleration

[G]

Push

[%]

Positioning

band [mm]

0 *

*

*

*

*

*

1 150.00

200.00

0.30

0.30

0

10.00

2 200.00

100.00

0.30

0.30

0

0.10

:

T1: 6 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)

Caution: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.
Always turn OFF the start signal after confirming that the start signal is currently ON and the
position complete output has turned OFF.

Speed

Position 1 Position 2

Position 1

T

1

T

1

Position 2

Note

Note

Command position

Start

Position complete

Completed position

Moving

Actuator movement