9.5 Detail Connection Diagram

(*1) The user must provide the two-paired shielded cable.

If cables other than the recommended brands are connected to [A] and [B], use those with a cable-sheath
outer diameter of 1.35 to 1.60 mm.

Accessories (Optional):
[1] Controller link cable CB-RCB-CTL002 (connector on both ends), length 200 mm
[2] Four-way junction, made by AMP: 5-1473574-4
[3] E-Con connector, made by AMP: 4-1473562-4 (green)
[4] Terminal resistor 220

: (with E-Con connector)

Of the above, [2], [3] and [4] are provided for the same number as the controller link cables. Therefore, not all
units are needed when multiple axes are used.

(*2) If the 24-V power supply is grounded to a plus terminal, do not ground FG of an SIO converter and PC.

Moreover, make sure to use an SIO isolator (RCB-ISL-SIO) if an ISO converter is not used when the 24-V
power supply is grounded to a plus terminal. (Refer to the next page.)

SIO converter

(*1) Two-paired shielded cable
Recommended

brand:

Taiyo Electric Wire & Cable

HK-SB/20276XL
2PX22AWG

Four-way junction (AMP: 5-1473574-4)

Yellow

Orange

Blue

Yellow

Orange

Blue

Housing color: Green

Controller link cable
CB-RCB-CTL002

E-Con connector (AMP: 4-1473562-4)

Controller 1

E-Con connector (AMP: 3-1473562-4)

Housing color: Orange

Controller 2

[B]

[A]

(*2)