6SHFL¿FDWLRQV

2. Specifications

2.1 Basic

Specifications

Specification item

Positioner type (with internal drive-

power cutoff relay)

Safety category type (with external drive-

power cutoff relay)

Model number

ACON-C

ACON-CG

Number of controlled axes

1 axis per unit

Power-supply voltage

24 VDC +10%/-10%

Standard specification/Support high

acceleration/deceleration

Support power-saving

Actuator Motor

type

Rated [A]

Maximum

(note 2)

Rated [A]

Maximum

(note 2)

10 W

1.3

4.4

1.3

2.5

20 W [Model number
code: 20]

1.3

4.4

1.3

2.5

30 W

1.3

4.0

1.3

2.2

20 W [Model number
code: 20]

RCA

/

RCA2

Exclusively for RA3, RA4
and TA5 types

1.7

5.1

1.7

3.4

2 W

0.8

4.6

5 W

1.0

6.4

Motor power

capacity
(Note 1)

RCL

10 W

1.3

6.4

Heat release

8.4 W

RCA 800

Pulse/rev

RCA-2-

………N 1048

Pulse/rev

RCA2

Other than RCA2-

………N 800 Pulse/rev

RA1L

‚SA1L

‚SA4L‚SM4L

715 Pulse/rev

RA2L

‚SA2L

‚SA5L‚SM5L

855 Pulse/rev

Encoder

resolution

RCL

RA3L

‚SA3L

‚SA6L‚SM6L

1145 Pulse/rev

Positioning command

Positioning points: 64 points as standard, 512 points at maximum (up to 768 points
for the network connection specifications)
The positioning points vary depending on the PIO pattern selection and parameter.

Backup memory

Position number data and parameters are stored in the nonvolatile memory.
Serial EEPROM life: Approx. 100,000 times of rewriting

PIO interface

24 VDC isolation, dedicated 16-point inputs/16-point outputs

PIO interface power supply

24 VDC ±10% (external supply)

LED indicator

SV (green) --- Whether or not the servo is on / ALM (red) --- Whether or not an
alarm is present.

Serial communication

RS485, 1 channel (conforming to the Modbus protocol)

Encoder interface

Incremental specification conforming to EIA RS-422A/423A

Forced release of electromagnetic brake

NOM/BK_RLS switch (front panel)
Actuator cable: 20 m or shorter

Cable length

I/O flat cable: 5 m or shorter

Dielectric strength

500 VDC 10 m

:

Surrounding air temperature

0 to 40

qC

Surrounding humidity

85% RH or below (non-condensing)

Surrounding environment

Free from corrosive gases.

Surrounding storage temperature

-10 to 65

qC

Surrounding storage humidity

90% RH or below (non-condensing)

Environment

Vibration resistance

10 to 57 Hz in all X/Y/Z directions / Single amplitude: 0.035 mm (continuous), 0.075
mm (intermittent)
57 to 150 Hz / 4.9 m/s

2

(continuous), 9.8 m/s

2

(continuing)

Protection class

Natural air cooling (IP20)

Weight

300 g or below

External dimensions

35 (W) x 178.5 (H) x 68.1 (D) mm

(Note 1) Rush current of 5 to 12 times the rated current is conducted for approximately 1 to 2 msec after turning the supply

on. Note that the rush current value varies depending on the impedance of the power line.

(Note 2) The maximum current is conducted at the servo motor exciting phase detection performed in the first servo on

processing after turning the power on (normally: approximately 1 to 2 seconds, maximum: 10 seconds).

* Select power supply of +24 VDC power supply of the “peak load support" specification or with sufficient capacity.