7. Operation <Practical Steps>

(2) Push & hold mode

The following explains how the actuator will move if an incremental position number is selected and input
and then a start signal is input while the actuator is moving in the push & hold mode.

z Positioning operation using the incremental position number
Example) If a position 2 command is input followed by a start signal while the actuator is moving to position 1,

the actuator will move to the position corresponding to the target position of the position 1 command
plus the incremental distance.
If the position table is set as follows, the actuator will move to the 215-mm position.

Position table (Field(s) within thick line must be entered.)

0

1

2

}

½

½

½

½

½

200.00

15.00

=

100.00

20.00

30.00

0.10

50

0

0

1

Position

[mm]

Speed

[mm/ss]

Positioning

band
[mm]

Incremental

Push

[%]

* On the teaching pendant screen, this sign indicates that the position is

specified in the incremental mode.

Incremental
feed

No.

Distance

Command position

Start

Position complete

Actuator movement

Speed

Position 1

Position 2

Initial target

position: 200 mm

Stopped position:

215 mm

100 mm/s

20 mm/s

Advertising