IAI America PCON-CFA User Manual

Page 113

Advertising
background image

4. PCON-CA/CF

A

CC-Link

107

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit Symbol

Description

Details

Current

Position

32bits

Data



32-bit Integer with a Symbol
The unit is 0.01mm.
(Example)
Read Value: 000003FF

H

= 1023 (decimal system) = 10.23mm

* When it is read in hexadecimal notation, input the negative

value using a compliment of 2.

4.9 (2)

Command

Current

32bits

Data



32-bit Integer
It shows the current value in the current command.
The unit is mA.
Read Value: 000003FF

H

= 1023 (decimal system) = 1023mA

4.9 (2)

Current

Speed

32bits

Data



32-bit Integer with a Symbol
It shows the current speed.
Positive Figure: Under movement in the opposite direction of home
Negative Figure: Under movement in the home direction
The unit is 0.01mm/sec.
(Example)
Read Value: 000003FF

H

= 1023 (decimal system)

= 10.23mm/sec

* When it is read in hexadecimal notation, input the negative

value using a compliment of 2.

4.9 (2)

Alarm

code

16bits

Data



16-bit Integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0

H

”.

Refer to the instruction manual for the controller main body for
the details of the alarms.

4.9 (2)

b15

EMGS Emergency Stop: “ON” for Emergency Stop Status

4.7.7 (2)

b14

PWR Controller Ready: “ON” for Ready

4.7.7 (1)

b13 ZONE2 Zone 2: “ON” for the current position within the zone set range 4.7.7 (12)
b12 ZONE1 Zone 1: “ON” for the current position within the zone set range 4.7.7 (12)

b11

b10

b9



Unavailable



b8

RMDS

Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently “MANU”
mode

4.7.7 (19)

b7

ALML

Light error status:
Turns ON when light alarm (threshold exceeded for number of
movement, etc.) that the operation can be continued with is
issued.
Note: ALM LED would not turn ON with a light error.

4.7.7 (31)

b6



Unavailable



b5

PSEL Pressing and a Miss: “ON” for pressing and a miss

4.7.7 (23)

b4

SV

Operation Ready: “ON” with Servo ON

4.7.7 (5)

b3

ALM Alarm: “ON” with alarm issue

4.7.7 (3)

b2

MOVE

Movement Signal:
“ON” with Actuator Movement

4.7.7 (9)

b1

HEND

Homing Completion
“ON” with Homing Completion

4.7.7 (6)

P

LC

In

pu

t

Status
Signal

b0

PEND

Positioning Completion Signal:
“ON” with Positioning Completion

4.7.7 (10)

Advertising
This manual is related to the following products: