IAI America PCON-CFA User Manual

Page 197

Advertising
background image

5. SCON-CA

CC-Link

191

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Address

Bit Symbol

Functions

Details

Acceleration

16bits

Data



Deceleration

16bits

Data



16-bit Integer
Set the acceleration and deceleration in the movement.
The unit is 0.01G and the settable range is from1 to 300.
(Example)
When it is 0.30G, set it as “30”.
When the movement command is issued with the value of “0” or
bigger than the max. acceleration/deceleration value, an alarm
is output.

5.9 (3)

Pressing

Current

Limit

Value

16bits

Data



16-bit Integer
Set the current limit in the pressing operation.
The settable range is between 0 (0%) and 510 (200%).
The actual settable range varies depending on each actuator.
(Refer to the catalog or instruction manual for the actuator).
When the movement command is set with the value bigger than
the max. pressing current value, an alarm is issued.

5.9 (3)

Load

Current

Threshold

16bits

Data



16-bit Integer
Set the current threshold in this register when whether or not
the load current exceeds the threshold is judged.
The settable range is between 0 (0%) and 510 (200%).
When the judgment is not to be performed, set it to “0”.

5.9 (3)

b15
b14



Unavailable



b13

NTC1

Anti-Vibration
Control Mode
Selection 1

b12

NTC0

Anti-Vibration
Control Mode
Selection 0

Select the anti-vibration control parameter set to
be used

NTC1 NTC0

Functions

OFF

OFF Anti-vibration control not used

OFF

ON Parameter set 1 selected

ON

OFF Parameter set 2 selected

ON

ON Parameter set 3 selected

5.7.11 (33)

b11

b10



Unavailable



b9

ASO1 Stop Mode 1

b8

ASO0 Stop Mode 0

Select the stop mode for standby

ASO1 ASO0

Functions

OFF

OFF Invalid (Servo is always ON)

OFF

ON

Servo is turned OFF after the time
set in Parameter No.36 is passed.

ON

OFF

Servo is turned OFF after the time
set in Parameter No.37 is passed.

ON

ON

Servo is turned OFF after the time
set in Parameter No.38 is passed.

5.7.11 (31)

b7

MOD1

P

LC

O

ut

pu

t

Control

signal 1

b6

MOD0

Acceleration/Deceleration Mode:

OFF/OFF for Trapezoid Pattern
OFF/ON for S-shaped Motion
ON/OFF for First-Order Lag Filter

5.7.11 (30)