3.

ACON-C/CG, PCON-C/CG

CC-Link

38

3.7.5 Full Direct Value Mode (Remote Device Station: No. of Occupied Stations: Four

stations)

This is the operation mode with all the values (target position, speed, etc.) set up directly using values from
PLC.
Set each value in the I/O data register.
The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

Robot Cylinder Function

:Direct Control

:Disabled

Homing

Positioning

Speed, Acceleration and Deceleration Settings

Pitch Feeding (Inching)

Pressing Operation

Speed change during the movement

Different Acceleration Speed

Operation in Deceleration

Pause

Zone Signal Output

PIO Pattern Selection

(1) PLC Address Composition (* “n” shows the head register address for each axis).

Parameter

No.84

Acon or Pcon side

Input register

PLC side

Acon or Pcon side

Output register

PLC side

RY n0 to nF

RX n0 to nF

RY (n+1)0 to (n+1)F

RX (n+1)0 to (n+1)F

RY (n+2)0 to (n+2)F

RX (n+2)0 to (n+2)F

RY (n+3)0 to (n+3)F

RX (n+3)0 to (n+3)F

RY (n+4)0 to (n+4)F

RX (n+4)0 to (n+4)F

RY (n+5)0 to (n+5)F

RX (n+5)0 to (n+5)F

Occupied Area

RY (n+6)0 to (n+6)F

Occupied Area

RX (n+6)0 to (n+6)F

System Area

RY (n+7)0 to (n+7)F

System Area

RX (n+7)0 to (n+7)F

RWw (n+0)

RWr (n+0)

Target Position

RWw (n+1)

Current Position

RWr (n+1)

RWw (n+2)

RWr (n+2)

Positioning Width

RWw (n+3)

Command Current

RWr (n+3)

RWw (n+4)

RWr (n+4)

Speed

RWw (n+5)

Current Speed

RWr (n+5)

RWw (n+6)

Alarm code

RWr (n+6)

Zone Value “+”

RWw (n+7)

RWr (n+7)

RWw (n+8)

RWr (n+8)

Zone Value “-”

RWw (n+9)

RWr (n+9)

Acceleration

RWw (n+A)

RWr (n+A)

Deceleration

RWw (n+B)

RWr (n+B)

Pressing Current

Limit Value

RWw (n+C)

RWr (n+C)

ACON

Occupied Area

PCON Load Current Threshold

RWw (n+D)

RWr (n+D)

Control signal 1

RWw (n+E)

Occupied Area

RWr (n+E)

3

Control signal 2

RWw (n+F)

Status Signal

RWr (n+F)

Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device stations.

The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.