(30) Stop Mode Selection (ASO1, ASO0)

Select the stop mode for the duration before the movement to the next position after a positioning is
completed.
If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power
consumption.
Refer to the instruction manual for the controller for more information.

ASO1

ASO0

Function

Reference

OFF

OFF Disabled

Set in delivery

OFF

ON

Automatic Servo OFF Method
Parameter No. 36 is valid for T

ON

OFF

Automatic Servo OFF Method
Parameter No. 37 is valid for T

ON

ON

Automatic Servo OFF Method
Parameter No. 38 is valid for T

PLC Output Signal

T

Movement

Command

Actuator

Moving

Servo

Condition

Servo ON

Condition

T : Waiting time (sec) before servo is

turned OFF after the positioning is completed

Target Position

In automatic servo OFF duration

(Green LED blinks)