3.

ACON-C/CG, PCON-C/CG

CC-Link

13

4) Full Direct Value Mode : This is the operation method with all the values (“Target Position”, “Speed”,

“Acceleration/Deceleration”, etc.) related to the position control set up directly
using the numerical values.
No. of Occupied Stations: Four Stations

5) Remote I/O Mode 2

: This is the operation method using CC-Link, instead of PIO (24CV I/O).

The current position and command current value reading functions are added to
the functions of (1).
No. of Occupied Stations: One Station

ACON or PCON
applicable to CC-Link

Actuator

Target Position: 100.00mm
Positioning Width: 0.10mm
Speed Setup: 100.0mm/s
Acceleration: 0.30G
Deceleration: 0.30G
Pressing Current Value: 50%
Load Current Threshold: 0
Zone +: 50.00mm
Zone - : 30.00mm

Flat cable

ACON or PCON

not applicable to CC-Link

In the case of the connection using PIO

In the case of the connection using CC-Link

ACON or PCON

applicable to CC-Link

Communications

cable