IAI America PCON-CFA User Manual

Page 207

Advertising
background image

5. SCON-CA

CC-Link

201

(3) I/O Signal Allocation

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit Symbol

Description

Details

Target

Position

32bits

Data



32-bit Signed Integer
Set the target position on the absolute coordinates.
The unit is 0.01mm and settable range is between –999999 to
+999999.
(Example)
When it is “+25.40mm”, set it as “2540”.
If the value larger than the value (0.2mm) inside the soft limit for
the parameter, the movement would be limited to the inside the
soft limit (0.2mm).
* When the input is performed in hexadecimal notation, input

the negative value using a compliment of 2.

5.9 (1)

Command

position
number

16bits

Data

PC1 –

PC512

16-bit Integer
For the operation, the position data is required, for which the
operation conditions have been set in advance using the
teaching tool such as the PC software.
Set up the position No. for which the data has been input using
this register.
The settable range is 0 to 767.
In the case that any value out of the range is set, or position No.
that has not been set is specified, an alarm is output.

5.9 (1)

b15

BKRL Brake Forcible Release: Brake Release with “ON”.

5.7.11 (18)

b14

RMOD

Operation Mode: “OFF” for “AUTO” Mode, “ON” for “MANU”
mode

5.7.11 (19)

b13
b12



Unavailable



b11

PMOD

Position/Simplified Direct Value Change-Over
“OFF” for Position Mode, “ON” for Simplified Direct Value Mode

5.7.11 (20)

b10



Unavailable



b9

CLBR Loadcell Calibration Command : “ON” to execute calibration

5.7.11 (32)

b8

JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home

5.7.11 (13)

b7

JOG- - Jog: “ON” for Movement to the Home Direction

5.7.11 (13)

b6

JVEL

Jog Speed/Inching Distance Change-Over
“OFF” for using the values set for the Parameter No. 26 “Jog
Speed” and Parameter No. 48 “Inching Distance”
“ON” for using the values set for the Parameter No. 47 “Jog
Speed 2” and Parameter No. 49 “Inching Distance 2”

5.7.11 (14)

b5

JISL

Jog/Inching Change-Over
“OFF” for Jog Operation, “ON” for Inching Operation

5.7.11 (15)

b4

SON Servo ON Command: “ON” for Servo ON

5.7.11 (5)

b3

RES Reset: “ON” for Reset Execution

5.7.11 (4)

b2

STP Pause: “ON” for Pause Command

5.7.11 (7)

b1

HOME Homing: “ON” for Homing Command

5.7.11 (6)

P

LC

O

ut

pu

t

Control

Signal

b0

CSTR Positioning Start: “ON” for Movement Command

5.7.11 (7)

Advertising
This manual is related to the following products: