IAI America PCON-CFA User Manual

Page 114

Advertising
background image

4. PCON-CA/CF

A

CC-Link

108

4.7.5 Full Direct Value Mode (Remote Device Station: No. of Occupied Stations: Four

stations)

This is the operation mode with all the values (target position, speed, etc.) set up directly using values from
PLC.
Set each value in the I/O data register.
The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

Robot Cylinder Function

:Direct Control

:Disabled

Homing

Positioning

Speed, Acceleration and Deceleration Settings

Pitch Feeding (Inching)

Pressing Operation

Speed change during the movement

Different Acceleration Speed

Operation in Deceleration

Pause

Zone Signal Output

PIO Pattern Selection

(1) PLC Address Composition (* “n” shows the head register address for each axis).

Parameter

No.84

PCON-CA/CFA side

Input register

PLC side

PCON-CA/CFA side

Output register

PLC side

RY n0 to nF

RX n0 to nF

RY (n+1)0 to (n+1)F

RX (n+1)0 to (n+1)F

RY (n+2)0 to (n+2)F

RX (n+2)0 to (n+2)F

RY (n+3)0 to (n+3)F

RX (n+3)0 to (n+3)F

RY (n+4)0 to (n+4)F

RX (n+4)0 to (n+4)F

RY (n+5)0 to (n+5)F

RX (n+5)0 to (n+5)F

Occupied Area

RY (n+6)0 to (n+6)F

Occupied Area

RX (n+6)0 to (n+6)F

System Area

RY (n+7)0 to (n+7)F

System Area

RX (n+7)0 to (n+7)F

RWw (n+0)

RWr (n+0)

Target Position

RWw (n+1)

Current Position

RWr (n+1)

RWw (n+2)

RWr (n+2)

Positioning Width

RWw (n+3)

Command Current

RWr (n+3)

RWw (n+4)

RWr (n+4)

Speed

RWw (n+5)

Current Speed

RWr (n+5)

RWw (n+6)

Alarm Code

RWr (n+6)

Zone Value “+”

RWw (n+7)

RWr (n+7)

RWw (n+8)

RWr (n+8)

Zone Value “-”

RWw (n+9)

Occupied Area

RWr (n+9)

Acceleration

RWw (n+A)

RWr (n+A)

Deceleration

RWw (n+B)

Total moving count

RWr (n+B)

Pressing Current

Limit Value

RWw (n+C)

RWr (n+C)

Load Current

Threshold

RWw (n+D)

Total moving

distance

RWr (n+D)

Control signal 1

RWw (n+E)

Status Signal 1

RWr (n+E)

3

Control signal 2

RWw (n+F)

Status Signal 2

RWr (n+F)

Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device stations.

The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.