IAI America PCON-CFA User Manual

Page 123

Advertising
background image

4. PCON-CA/CF

A

CC-Link

117

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Signal

name

Description

Details

Current

Position

32bits

Data



32-bit Signed Integer

The unit is 0.01mm.

(Example)

Read Value: 000003FF

H

= 1023 (decimal system) =

10.23mm

* When the value is read in hexadecimal notation, the

negative figure is expressed as a compliment of 2.

4.9 (3)

Command

Current

32bits

Data



32-bit Integer

It shows the current value in the current command.

The unit is mA.

Read Value: 000003FF

H

= 1023 (decimal system) = 1023mA

4.9 (3)

Current

Speed

32bits

Data



32-bit Signed Integer

It shows the current speed.

Positive Figure: Under movement in the opposite direction of

the home

Negative Figure: Under movement in the home direction

The unit is 0.01mm/sec.

(Example)

Read Value: 000003FF

H

= 1023 (decimal system) =

10.23mm/sec

* When it is read in hexadecimal notation, input the

negative value using a compliment of 2.

4.9 (3)

Alarm

Code

16bits

Data



16-bit Integer

When an alarm is issued, the alarm code is output.

When any alarm is not issued, it is “0”.

Refer to the instruction manual for the controller main body

for the details of the alarms.

4.9 (3)

Total

moving

count

32bits

Data



32-bit integer

(unit: times)



Total

moving

distance

32bits

Data



32-bit integer

(unit: 1m)



b15
b14
b13
b12

b11

b10

b9
b8
b7
b6
b5
b4
b3
b2
b1



Unavailable



PLC Input

Status

Signal 1

b0

ALML

Light error status:

Turns ON when light alarm (threshold exceeded for number

of movement, etc.) that the operation can be continued with

is issued.

Note: ALM LED would not turn ON with a light error.

4.7.7 (31)