5. SCON-CA

CC-Link

169

(3) I/O Signal Allocation

The controller's I/O port signal varies depending on the parameter No. 25 setting.
(Refer to instruction manual for the controller main body for more information).

Parameter No. 25 setting

Positioning mode

Teaching mode

256point mode

0

1

2

Classification Port

No.

Symbol

Signal Names

Symbol

Signal Names

Symbol

Signal Names

0

PC1

PC1

PC1

1

PC2

PC2

PC2

2

PC4

PC4

PC4

3

PC8

PC8

PC8

4

PC16

PC16

PC16

5

PC32

Command position

No.

PC32

Command position No.

PC32

6



MODE

Teaching Mode

Command

PC64

7



USL

Jog/Inching selection

PC128

Command position No.

8



Unavailable

JOG+

+ Jog



Unavailable

9

BKRL

Forced brake release

JOG-

- Jog

RKRL

Forced brake release

10

RMOD

Operation mode

RMOD

Operation mode

RMOD

Operation mode

11

HOME

Return to origin

HOME

Return to origin

HOME

Return to origin

12

*STP

Pause

*STP

Pause

*STP

Pause

13

CSTR

Positioning Start

CSTR/

PWRT

Positioning Start/

Position Data Import

Command

CSTR

Positioning Start

14

RES

Reset

RES

Reset

RES

Reset

PLC Output㸢

SCON-CA Input

15

SON

Servo ON Command

SON

Servo ON Command

SON

Servo ON Command

0

PM1

PM1

PM1

1

PM2

PM2

PM2

2

PM4

PM4

PM4

3

PM8

PM8

PM8

4

PM16

PM16

PM16

5

PM32

Completion position

No.

PM32

Completion position

No.

PM32

6

MOVE

Moving Signal

MOVE

Moving Signal

PM64

7

ZONE1

Zone 1

MODES

Teaching Mode Signal

PM128

Completion position

No.

8

PZONE/

ZONE2

Position zone status/

Zone 2

PZONE/

ZONE1

Position zone status/

Zone 1

PZONE/

ZONE1

Position zone status/

Zone 1

9

RMDS

Operation Mode

Status

RMDS

Operation Mode Status

RMDS

Operation Mode Status

10

HEND

Return to origin end

HEND

Return to origin end

HEND

Return to origin end

11

PEND

Positioning end Signal

PEND/

WEND

Positioning end Signal/

Position Data

Import Completion

PEND

Positioning end Signal

12

SV

Operation preparation

end

SV

Operation preparation

end

SV

Operation preparation

end

13

*EMGS

Emergency stop

*EMGS

Emergency stop

*EMGS

Emergency stop

14

*ALM

Alarm

*ALM

Alarm

*ALM

Alarm

SCON-CA

Output

PLC Input

15

*BALM

Battery Alarm

*BALM

Battery Alarm

*BALM

Battery Alarm

The symbol with a * mark shows the ON signal in normal condition.
The signals describing as “Unavailable” are not controlled. (ON/OFF is undefined).