5. SCON-CA

CC-Link

197

PLC Input (* “n” shows the head register address per each axis).

Address

one word = 16 bits

RX (n+0)

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

Controller
Output
Port No.

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Address

one word = 16 bits

RWr (n+0) b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Current
Position
(Slave Word)

RWr (n+1) b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Current

Position
(Host Word)

When the negative figure, it is expressed using the complement of 2.

RWr (n+2) b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Command
Current
(Slave Word)

32

,7

68

16

,3

84

8,

19

2

4,

09

6

2,

04

8

1,

02

4

51

2

25

6

12

8

64

32

16

8

4

2

1

RWr (n+3) b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Command
Current
(Host Word)

























52

4,

28

8

26

2,

14

4

13

1,

07

2

65

,5

36

(3) I/O Signal Allocation

Refer to “5.7.2 Remote I/O Mode (3) I/O Signal Allocation” for each PIO pattern signal allocation.

The signal allocation for the Command Current and Current Position, is shown in the following table.

Signal Type

Bit Signal Name

Description

Details

Current

Position

32bits

Data



32-bit Signed Integer
The unit is 0.01mm.
(Example)
Read Value: 000003FF

H

= 1023 (decimal system) = 10.23mm

* When the value is read in hexadecimal notation, the

negative figure is expressed as a compliment of 2.



P

LC

In

pu

t

Command

Current

32bits

Data



32-bit Integer
It shows the current value in the current command.
The unit is 1mA.