5. SCON-CA

CC-Link

195

5.7.6 Remote I/O Mode 2 (Remote Device Station: No. of Occupied Stations: One Station)

This is the operation mode with the position No. set up as the same as using PIO (24V I/O). Set the position
data using the teaching tool such as the personal computer application software for RC. The number of
operable positions varies depending on the parameter No. 25 “PIO Pattern” setting.
The I/O specifications for the PIO pattern are described as follows (Refer to instruction manual for the
controller main body for more information).

Parameter No. 25 Set Value

Operation Mode

I/O Specifications

0

Positioning mode

64 positioning points and 2 zone output points

1

Teaching mode

64 positioning points and 1 zone output point
The positioning and jog operations are available.
The current position can be written on the setup position data.

2

256 point mode

256 positioning points and 1 zone output point

3

512 point mode

512 positioning points and no zone output point

4

Electromagnetic

valve mode 1

7 positioning points and 2 zone output points
The direct operation command is available for each position No.
The positioning completion signal is output for each position No.

5

Electromagnetic

valve mode 2

3 positioning points and 2 zone output points
It is operated with the Forward/Backward/Intermediate
Position Commands.
The positioning completion signal is output individually for
each Forward End/Backward End/Intermediate Positions.

6

Force Control Mode 1

(requires dedicated loadcell)

32 positioning points and 1 zone output points

7

Force Control Mode 2

(requires dedicated loadcell)

5 positioning points and 1 zone output points
The direct operation command is available for each position No.
The positioning completion signal is output for each position No.

The actuator's effective main functions that can be controlled using this mode, are as shown in the following table.

PIO Pattern

Actuator Function

0:

Positioning

mode

1:

Teaching

mode

2:

256 point

mode

3:

512 point

mode

4:

Electromagnetic

valve mode 1

5:

Electromagnetic

valve mode 2

6:

Force

Control

Mode 1

7:

Force

Control

Mode 2

Homing

Positioning

Speed, Acceleration and
Deceleration Settings

Pitch Feeding (Inching)

Pressing Operation

Speed change during
the movement

Different Acceleration Speed,
Operation in Deceleration

Pause

(*1)

Zone Signal Output

PIO Pattern Selection
(Set using the parameters)

: Operation Available 㬍: Operation Unavailable

(*1) It is available when the parameter No. 27 “Movement Command Type” is set to “0”. Turning “OFF” the

“Movement Command” can stop the system temporarily.