IAI America PCON-CFA User Manual

Page 209

Advertising
background image

5. SCON-CA

CC-Link

203

5.7.8 Half Direct Value Mode 2 (Remote Device Station: No. of Occupied Stations: Two

Stations)

This mode provides an operation method to utilize the force control (loadcell value feedback pressing) and
also indicate the target position from PLC, positioning band width, speed, acceleration/deceleration speed and
pressing current directly with inputting values.
Set the each value in I/O area. When the zone function is used, set it using the parameter Nos. 1, 2, 23 and 24.
The actuator's effective main functions that can be controlled using this mode, are as shown in the following
table.

Actuator Function

:Direct Control

:Indirect Control

:Disabled

Remarks

Homing

Positioning

Speed, Acceleration and Deceleration Settings

Pitch Feeding (Inching)

Pressing Operation

Speed change during the movement

Different Acceleration Speed
Operation in Deceleration

Pause

Zone Signal Output

Parameter setting is required.

PIO Pattern Selection

(1) PLC Channel Composition (* “n” shows the head node address for each axis).

Parameter

No.84

SCON-CA side

Input register

PLC side

SCON-CA side
Output register

PLC side

RY n0 to nF

RX n0 to nF

RY (n+1)0 to (n+1)F

RX (n+1)0 to (n+1)F

Occupied Area

RY (n+2)0 to (n+2)F

Occupied Area

RX (n+2)0 to (n+2)F

System Area

RY (n+3)0 to (n+3)F

System Area

RX (n+3)0 to (n+3)F

RWw (n+0)

RWr (n+0)

Target Position

RWw (n+1)

Current Position

RWr (n+1)

RWw (n+2)

RWr (n+2)

Positioning Width

RWw (n+3)

Force Feedback Data

RWr (n+3)

Speed

RWw (n+4)

RWr (n+4)

Acceleration/Deceleration

RWw (n+5)

Current Speed

RWr (n+5)

Pressing Current Limit

Value

RWw (n+6)

Alarm code

RWr (n+6)

2

Control signal

RWw (n+7)

Status Signal

RWr (n+7)

Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device

stations.
The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.

Advertising