Scon-ca cc-link – IAI America PCON-CFA User Manual

Page 172

Advertising
background image

5. SCON-CA

CC-Link

166

x

SCON-CA Output o PLC Input side (* “n” shows the head register address per each axis).

SCON-CA side DO and Output data register

Position/Simplified

Direct Value Mode 2

Half Direct Value

Mode 2

Remote I/O mode 3

Half Direct Value

Mode 3

PLC address

Number of occupied

stations: 1 Station

Number of occupied

stations: 2 Stations

Number of occupied

stations: 4 Stations

Number of occupied

stations: 1 Station

RY n0 – nF

Occupied Area

Port No.0 – 15

RY

(n+1)0 – (n+1)F

System Area

System Area

RY

(n+2)0 – (n+2)F

Occupied Area

Occupied Area

RY

(n+3)0 – (n+3)F

System Area

System Area

RY

(n+4)0 – (n+4)F

RY

(n+5)0 – (n+5)F

RY

(n+6)0 – (n+6)F

RY

(n+7)0 – (n+7)F

RWr (n+0)

RWr (n+1)

Current Position

Current Position

Current Position

Current Position

RWr (n+2)

Completed Position

No.

(Simplified Alarm ID)

RWr (n+3)

Status Signal

Force Feedback

Data

Force Feedback

Data

Command Current

RWr (n+4)

RWr (n+5)

Current Speed

Current Speed

RWr (n+6)

Alarm code

Alarm code

RWr (n+7)

Status Signal

Status Signal

RWr (n+8)

RWr (n+9)

RWr (n+A)

RWr (n+B)

RWr (n+C)

RWr (n+D)

RWr (n+E)

RWr (n+F)

Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device

stations.
The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.

Advertising
This manual is related to the following products: