5. SCON-CA

CC-Link

192

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Address

Bit Symbol

Functions

Details

b5

GSL1

Servo Gain
Parameter Set
Selection 1

b4

GSL0

Servo Gain
Parameter Set
Selection 0

Set the parameter for servo gain switchover

GSL1 GSL0

Function

OFF

OFF Parameter set 0 selected

OFF

ON Parameter set 1 selected

ON

OFF Parameter set 2 selected

ON

ON Parameter set 3 selected

5.7.11 (33)

b3

INC

Incremental Command
“OFF” for Absolute Position Command, “ON” for Relative
Position Command

5.7.11 (24)

b2

DIR

Pressing Direction Setup:
“OFF” for the direction reducing the positioning width from the
target position, “ON” for the direction adding the positioning
width from the target position

5.7.11 (22)

b1

PUSH

Pressing Setup:
“OFF” for Positioning Operation, “ON” for Pressing Operation

5.7.11 (21)

Control

signal 1

b0



Unavailable



b15

BKRL Brake Forcible Release: “ON” for brake release

5.7.11 (18)

b14

RMOD

Operation mode:
“OFF” for Auto mode, “ON” for MANU mode

5.7.11 (19)

b13
b12

b11

b10



Unavailable



b9

CLBR Loadcell Calibration Command : “ON” to execute calibration

5.7.11 (32)

b8

JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home

5.7.11 (13)

b7

JOG- - Jog: “ON” for Movement to the Home Direction

5.7.11 (13)

b6

JVEL

Jog Speed/Inching Distance Change-Over:
“OFF” for using the values set using the Parameter No. 26 “Jog
Speed” and Parameter No. 48 “Inching Distance”
“ON” for using the values set using the Parameter No. 47 “Jog
Speed 2” and Parameter No. 49 “Inching Distance 2”

5.7.11 (14)

b5

JISL

Jog/Inching Change-Over:
“OFF” for Jog Operation, “ON” for Inching Operation

5.7.11 (15)

b4

SON Servo ON Command: “ON” for Servo ON

5.7.11 (5)

b3

RES Reset: “ON” for Reset Execution

5.7.11 (4)

b2

STP Pause: “ON” for Pause Command

5.7.11 (7)

b1

HOME Homing: “ON” for Homing Command

5.7.11 (6)

P

LC

O

ut

pu

t

Control

signal 2

b0

DSTR Positioning Start: “ON” for Movement Command