IAI America PCON-CFA User Manual

Page 217

Advertising
background image

5. SCON-CA

CC-Link

211

(1) PLC Address Composition (* “n” shows the head register address for each axis).

Parameter

No.84

SCON-CA side

DI and Input register

PLC side

SCON-CA side

DO and Output register

PLC side

Port No. 0 to 15

RY n0 to nF

Port No. 0 to 15

RX n0 to nF

System Area

RY (n+1)0 to (n+1)F

System Area

RX (n+1)0 to (n+1)F

RWw (n+0)

RWr (n+0)

RWw (n+1)

Current Position

RWr (n+1)

RWw (n+2)

RWr (n+2)

4

Occupied Area

RWw (n+3)

Force Feedback

Data

RWr (n+3)

Note: The Occupied Area stands for the area occupied by means of the setting of the number of remote device

stations.
The System Area stands for the system area of the remote device station.
These areas are not used for any other purpose. Also take care about duplicating the use of the data register.

(2) I/O Signal Allocation for each Axis

The I/O signal for each axis consists of 1 word for each I/O bit register.
The I/O signal for each axis consists of 4 words for each I/O data register.

z

The channel to be controlled with the port number is to be controlled by the ON/OFF signals in bit unit.

z

The current position is expressed using 2-word (32 bits) binary data (Unit: 0.01mm).

z

The force feedback data is expressed using 2-word (32 bits) binary data (Unit: 0.01N).

PLC Output (* “n” shows the head register address per each axis).

Address

one word = 16 bits

RY (n+0)

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

Controller

Input Port
No.

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Advertising