4. PCON-CA/CF

A

CC-Link

116

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Address

Bit

Symbol

Functions

Details

b2

DIR

Pressing Direction Setup:
“OFF” for the direction reducing the positioning width from
the target position, “ON” for the direction adding the
positioning width from the target position

4.7.7 (22)

b1

PUSH

Pressing Setup:

“OFF” for Positioning Operation, “ON” for Pressing
Operation

4.7.7 (21)

Control

signal 1

b0



Unavailable



b15

BKRL

Brake Forcible Release: “ON” for brake release

4.7.7 (18)

b14

RMOD

Operation mode:
“OFF” for Auto mode, “ON” for MANU mode

4.7.7 (19)

b13
b12

b11

b10

b9



Unavailable



b8

JOG+

+ Jog: “ON” for Movement in the Opposite Direction of
Home

4.7.7 (13)

b7

JOG-

- Jog: “ON” for Movement to the Home Direction

4.7.7 (13)

b6

JVEL

Jog Speed/Inching Distance Change-Over:
“OFF” for using the values set using the Parameter No. 26
“Jog Speed” and Parameter No. 48 “Inching Distance”
“ON” for using the values set using the Parameter No. 47
“Jog Speed 2” and Parameter No. 49 “Inching Distance 2”

4.7.7 (14)

b5

JISL

Jog/Inching Change-Over:
“OFF” for Jog Operation, “ON” for Inching Operation

4.7.7 (15)

b4

SON

Servo ON Command: “ON” for Servo ON

4.7.7 (5)

b3

RES

Reset: “ON” for Reset Execution

4.7.7 (4)

b2

STP

Pause: “ON” for Pause Command

4.7.7 (11)

b1

HOME

Homing: “ON” for Homing Command

4.7.7 (6)

P

LC

O

ut

pu

t

Control

signal 2

b0

DSTR

Positioning Start: “ON” for Movement Command

4.7.7 (8)