IAI America PCON-CFA User Manual

Page 134

Advertising
background image

4. PCON-CA/CF

A

CC-Link

128

(12) Zone 1

(ZONE 1)

Zone 2

(ZONE 2)

Position Zone (PZONE)

These signals are turned ON when the current position of the actuator is within the set area and turned
OFF when the current position is out of the set area.
1) Zone 1, Zone 2

The zone is set using the user parameters.
The Zone 1 Signal is set using the parameter No. 1 “Zone 1 “+” Side” and No. 2 “Zone 1 “-” Side”.
The Zone 2 Signal is set using the parameter No. 23 “Zone 2 “+” Side” and No. 24 “Zone 2 “-” Side”.
The Zone 1 Signal and Zone 2 Signal become effective when the homing operation is completed.
After that, even during the servo OFF, it is effective.

2) Position Zone

The zone is set using the position table I/O data register.
In the case of the Position/Simplified Direct Value Mode, the PZONE signal is set using the position
table.
In the case of the Full Direct Value Mode, the PZONE signal is set using the Zone Value Register.
(*) In the Half Direct Value Mode, there is no PZONE signal.
The PZONE signal becomes effective with the movement command after the homing operation. After
that, even during the servo OFF, it is effective.

PLC Input Signal

PLC Input Signal

PLC Input Signal

Zone Signal

Actuator Operation

Home

Zone Setting

"-" Side

Zone Setting

"+" Side

"+" Direction