Pcon-ca/cf a cc-link, Applicable to cc-link actuator – IAI America PCON-CFA User Manual

Page 90

Advertising
background image

4. PCON-CA/CF

A

CC-Link

84

2) Position/Simplified Direct Value Mode : This is the operation method with the position No. set up.

Whether if setup the target position using a value directly by means
of the change over of the control signal, or using the value
registered on the position data, can be selected.
For “Speed”, “Acceleration/Deceleration” and “Positioning Width”,
use the values already registered on the position data. The settable
No. of position data items is max 768 points.
No. of Occupied Stations: One Station

3) Half Direct Value Mode : This is the operation method with the “Speed”, “Acceleration/Deceleration”,

“Pressing Current Value” set up directly using the numerical values, in addition to
the “Target Position”.
No. of Occupied Stations: Two Stations

Target Position : 100.00mm

+

Position No.0

PCON-CA/CFA

applicable to CC-Link

Actuator

No.

0

Speed

[mm/s]

Acceleration

[G]

Deceleration

[G]

Pressing

[%]

300.00

0.30

0.30

0

Target Position : 100.00mm

Positioning Width : 0.10mm

Speed Setup : 100.0mm/s

Acceleration/Deceleration : 0.30G

Pressing Current Value : 50%

PCON-CA/CFA

applicable to CC-Link

Actuator

Advertising