9-4

IM 04L21B01-01EN

• Rolling average

• On/Off

To take the rolling average of the measured results, select

On.

• Interval

Select the sampling interval when taking the rolling average from the following: The

sampling interval takes on a value that is an integer multiple of the scan interval.
For example, if the sampling interval is set to 5 s when the scan interval is 2 s, the
actual sampling interval is 6 s.

• Number of samples

Set the number of samples for the rolling average using an integer between 1 and

1500.

The rolling average time is equal to the sampling interval × the number of samples.

Note

• If the number of data points in the moving average has not reached the specified number

of samples immediately after computation is started, the average of the available data is
calculated.

• Computation error data is excluded from the rolling average computation.
• If the computed data exceeds the upper or lower limit, the data is clipped at the upper or

lower limit, and the rolling average is computed. The upper and lower limit is “±100000000”
excluding the decimal point. The decimal place is the same as that of the span lower limit.

• Memory sample > On/Off

Select

On to record the computed data of the target channels.

Settings

Description

On

Computed data is recorded. Waveforms are displayed on the trend display.

Off

Computed data is not recorded. Even when registered in a display group,

waveforms are not displayed in the trend display.

• Math

• Value on Error

Specify whether to set the display for a computation error to

+Over or –Over.

• Value on Overflow > SUM, AVE

Specify how to handle overflow data when it is detected in the SUM or AVE

computation of TLOG or CLOG. This setting is also applied to report generation.

Settings

Description

Error

Sets the computed result to computation error.

Skip

Discards the overflow data and continues the computation.

Limit

Uses a limit value in place of the overflow data and continues the computation.

• Value on Overflow > MAX, MIN, P-P

Specify how to handle overflow data when it is detected in the MAX, MIN, or P-P

computation of TLOG or CLOG. This setting is also applied to report generation.

Settings

Description

Over

Uses the overflow data as-is.

Skip

Discards the overflow data and continues the computation.

9.1 Setting the Expression, Measurement Range, Alarm, Tag, and Data Storage on Computation Channels