6 wiring the power supply, 6 wiring the power supply -15, App index – Yokogawa Value Series FX1000 User Manual

Page 264: Warning

Advertising
background image

12-15

IM 04L21B01-01EN

Installation and W

iring

3

2

1

4

5

6

7

8

9

10

11

12

13

14

App

Index

12.6 Wiring the Power Supply

Precautions to Be Taken While Wiring the Power Supply

Make sure to follow the warnings below when wiring the power supply. Failure to do so
may cause electric shock or damage to the instrument.

WARNING

• To prevent electric shock, ensure that the power supply is turned off.
• To prevent fire, use 600 V PVC insulated wires (AWG20 to AWG16; JISC3307)

or wires or cables with equivalent or better performance.

• Make sure to earth ground the protective earth terminal through a grounding

resistance of 100 Ω or less before you turn on the power.

• Use crimp-on lugs (designed for 4 mm screws) with insulation sleeves to

connect both the power cord and the protective ground.

Crimp-on lug (designed for 4 mm screws) with an insulation sleeve

• To prevent electric shock, be sure to close the transparent cover for the power

supply wires.

• Provide a power switch (double-pole type) on the power supply line to separate

the FX from the main power supply. Use labels to indicate that this switch is for
cutting off the power supply to the FX and to indicate ON and OFF.

Switch specifications

Steady-state current rating: 1 A or more (other than
/P1); 3 A or more (/P1)

Inrush current rating: 60 A or more (other than /P1);
70 A or more (/P1)

Use a switch that complies with IEC60947-1 and
IEC60947-3.

• Connect a fuse (between 2 A and 15 A) to the power supply line.
• Do not add a switch or fuse to the ground line.

Use a power supply that meets the following conditions:

Item

Condition (Other than /P1)

Condition (/P1)

Rated supply voltage

100 to 240 VAC

24 VDC/AC

Allowable power supply

voltage range

90 to 132, 180 to 264 VAC

21.6 to 26.4 VDC/AC

Rated power supply

frequency

50/60 Hz

50/60 Hz (for AC)

Allowable power supply

frequency range

50/60 Hz ± 2%

50/60 Hz ± 2% (for AC)

Maximum power

consumption

35 VA (100 V), 45 VA (240 V) 18 VA (for DC), 30 VA (for AC)

Note

Do not use a supply voltage of 132 to 180 VAC, as this may have adverse effects on the
measurement accuracy.

Advertising