• Recording Conditions of Event Data

Item

Description

Source channels

Same as the display data.

Sampling interval

Choices are available in the range of 125 ms to 10 min. However, you

cannot specify an interval that is faster than the scan interval.

File creation

A file is created when the specified data length is reached.

Files are also created in the following cases.

• When a file is created manually.

• When the memory sampling is stopped.

• When file creation is executed with the event action function.

• After recovering from a power failure.

Mode

The available modes are

Free (continuously record), Single, and

Repeat. The recording operation varies depending on the mode as

follows:

Free

Press the START key to start recording (memory start) and the STOP

key to stop the recording (memory stop) .

Time

File

File

File

Adding data

Single

Pressing the START key places the FX in the trigger-wait state. After

a trigger event occurs, the FX will record data for the set time (data

length). From this point, the FX does not record even if the trigger

condition is met.

Time

File

Trigger condition met

Repeat

Pressing the START key places the FX in the trigger-wait state. After

a trigger event occurs, the FX will record data for the set time (data

length). The FX enters the trigger-wait sate again and keeps recording

the data for a specified time (data length) each time the trigger condition

is met. To stop recording event data, press STOP.

Time

File

File

Trigger condition met Trigger condition met

Pretrigger of Event Data

The pretrigger can be specified in trigger mode.

This function is used to save the data before the point where the trigger condition

is met as event data. This function is convenient when you wish to record the data

before the occurrence of a certain event such as when an alarm occurs.

Specify the pretrigger as a percentage (0, 5, 25, 50, 75, 95, or 100%) of the recording

time (data length) of the event data. If set to 0%, the data after the trigger condition is

met is recorded.

Time

Trigger condition met

Data before

the trigger

Data after

the trigger

Trigger for Starting the Event Data Recording

When set to trigger mode, you can set various conditions for starting the recording.
Example: Key operation, alarm occurrence, specific time, or remote control