GDS-2000A Programming Manual

110

Reference Commands

:REF<X>:DISPlay ....................................................... 110

:REF<X>:TIMebase:POSition .................................... 110

:REF<X>:TIMebase:SCALe ........................................ 111

:REF<X>:OFFSet ........................................................ 111

:REF<x>:SCALe .......................................................... 112

:REF<X>:DISPlay

Description

Sets or queries a reference waveform to be shown
on the display. A reference waveform must first be
saved before this command can be used.

Syntax

:REF<x>:DISPlay { OFF| ON| ? }

Parameter

<X>

Reference waveform 1, 2, 3 ,4.

OFF

Turns the selected reference
waveform off

ON

Turns the selected reference
waveform on

Return parameter

Returns the status of the selected reference
waveform. (OFF, ON)

Example

:REF1:DISPlay ON

Turns on reference1 (REF 1) on the display.

:REF<X>:TIMebase:POSition

Description

Sets or returns the selected reference waveform
time base position.

Syntax

:REF<X>:TIMebase:POSition { <NRf> | ?}

Related
commands

:REF<X>:DISPlay

Set

Query

Set

Query