Search:trigger:bus:b1:lin:condition – GW Instek GDS-2000A series Programming Manual User Manual
Page 218

GDS-2000A Programming Manual
218
String contents:
x = don’t care
1 = binary 1
0 = binary 0
Example
:SEARCH:TRIGger:BUS:B1:CAN:DATa:SIZe 1
:SEARCH:TRIGger:BUS:B1:CAN:DATa:VALue
"01010X1X"
:SEARCH:TRIGger:BUS:B1:CAN:DATa:VALue?
>01010X1X
:SEARCH:TRIGger:BUS:B1:LIN:CONDition
Description
Sets or returns the LIN search trigger condition.
Requirements: Firmware version V1.19 or later with
DS2-LA8 (or DS2-LA16).
Syntax
:SEARCH:TRIGger:BUS:B1:LIN:CONDition
{{SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|S
LEEP|ERRor|?}
Parameter/
Return parameter
SYNCField
Sets the LIN search trigger condition
to the sync field.
IDentifier
Sets the LIN search trigger condition
to identifier field.
DATA
Sets the LIN search trigger condition
to the data field.
IDANDDATA
Sets the LIN search trigger condition
to identifier and data field
WAKEup
Sets the LIN search trigger condition
to wake up.
SLEEP
Sets the LIN search trigger condition
to sleep.
ERRor
Sets the LIN search trigger condition
to error.
Set
Query