Trigger:bus:b1:parallel:value, Trigger:logic:function – GW Instek GDS-2000A series Programming Manual User Manual
Page 145

COMMAND DETAILS
145
:TRIGger:BUS:B1:PARallel:VALue
Description
Sets or queries the triggering data value for the
Parallel bus.
Syntax
:TRIGger:BUS:B1:PARallel:VALue {string | ? }
Related
commands
:BUS1:PARallel:WIDth
Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double
quotes, "string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example1
:BUS1:PARallel:WIDth 8
:TRIGger:BUS:B1:PARallel:VALue "1x1x0101"
Sets the value to 1x1x0101
Example 2
:TRIGger:BUS:B1:PARallel:VALue?
1X1X0101
:TRIGger:LOGic:FUNCtion
Description
Sets or queries the Boolean logical for the logic
trigger. Only available for firmware V1.18 or
above.
Syntax
:TRIGger:LOGic:FUNCtion {AND|NAND|NOR|OR|?}
Related
commands
:TRIGger:LOGic:PATtern:INPut:D<X>
Set
Query
Set
Query