D<x>:label:display – GW Instek GDS-2000A series Programming Manual User Manual
Page 235

COMMAND DETAILS
235
Parameter
<X>
Digital Channel D(0 to 15)
<string>
The string must be no more than 8
characters and only contain
alphanumeric characters in addition
to period, dash and underscore
characters. The string must be
enclosed in double quotes, “string”.
Return parameter <string>
Returns the label for the selected
digital channel. No return indicates
that there has not been a file label
assigned for the selected digital
channel.
Example1
:D0:LABel "D0_lab"
Sets the D0 label as "D0_lab".
Example2
:D0:LABel?
D0_lab
:D<X>:LABel:DISPlay
Description
Turns the label on/off for the selected digital
channel or returns its status.
Syntax
:D<X>:LABel:DISPlay { OFF | ON | ? }
Related
commands
:D<X>:LABel
Parameter
<X>
Digital channel D(0 to 15)
OFF
Turns the file label off for the selected
digital channel.
ON
Turns the file label on for the selected
digital channel.
Return parameter
Returns the status of the label for the selected
digital channel (ON, OFF).
Set
Query