Trigger:external:probe:type, Trigger:external:probe:ratio, Trigger:bus:type – GW Instek GDS-2000A series Programming Manual User Manual
Page 134

GDS-2000A Programming Manual
134
:TRIGger:EXTERnal:PROBe:TYPe
Description
Sets or queries the external probe type.
Syntax
:TRIGger:EXTERnal:PROBe:TYPe { VOLTage | CURRent
| ? }
Related
commands
:TRIGger:EXTERnal:PROBe:RATio
Parameter
VOLTage
Voltage
CURRent
Current
Return parameter
Returns the probe type.
Example
:TRIGger:EXTERnal:PROBe:TYPe?
CURRENT
:TRIGger:EXTERnal:PROBe:RATio
Description
Sets or queries the external probe ratio
(attenuation).
Syntax
:TRIGger:EXTERnal:PROBe:RATio {<NRf> | ?}
Related
commands
:TRIGger:EXTERnal:PROBe:TYPe
Parameter
<NRf>
External probe attenuation factor.
Return parameter <NR3>
Returns the probe attenuation factor.
Example
:TRIGger:EXTERnal:PROBe:RATio?
5.000000e+01
:TRIGger:BUS:TYPe
Description
Returns the current bus type.
Syntax
:TRIGger:BUS:TYPe?
Return parameter 12C
I2C mode
Set
Query
Set
Query
Query