Search:trigger:bus:b1:can:condition – GW Instek GDS-2000A series Programming Manual User Manual
Page 212

GDS-2000A Programming Manual
212
Related
commands
:BUS1:PARallel:WIDth
Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double
quotes "string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example 1
:BUS1:PARallel:WIDth 8
:SEARCH:TRIGger:BUS:B1:PARallel:VALue "1x1x0101"
Sets the value to 1x1x0101
Example 2
:SEARCH:TRIGger:BUS:B1:PARallel:VALue?
1X1X0101
:SEARCH:TRIGger:BUS:B1:CAN:CONDition
Description
Sets or returns the CAN search trigger condition.
Requirements: Firmware version V1.19 or later with
DS2-LA8 (or DS2-LA16).
Syntax
:SEARCH:TRIGger:BUS:B1:CAN:CONDition
{SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|
ACKMISS|STUFFERR|?}
Parameter/ Return
parameter
SOF
Sets search to trigger on a start of
frame
FRAMEtype
Sets search to trigger on the type of
frame
Identifier
Sets search to trigger on a matching
identifier
DATA
Sets search to trigger on matching data
Set
Query