Trigger:bus:b1:lin:errtype – GW Instek GDS-2000A series Programming Manual User Manual
Page 158

GDS-2000A Programming Manual
158
Parameter/
Return parameter
<string>
The size of the string depends on the
data size setting. The string must be
enclosed in double quotes, “string”.
String contents:
x = don’t care
1 = binary 1
0 = binary 0
Example
:TRIGger:BUS:B1:LIN:DATa:SIZe 1
:TRIGger:BUS:B1:LIN:DATa:VALue "01010X1X"
:TRIGger:BUS:B1:LIN:DATa:VALue?
>01010X1X
:TRIGger:BUS:B1:LIN:ERRTYPE
Description
Sets or returns the error type be used for the LIN
trigger.
Requirements: Firmware version V1.19 or later with
DS2-LA8 (or DS2-LA16).
Syntax
:TRIGger:BUS:B1:LIN:ERRTYPE
{SYNC|PARIty|CHecksum|?}
Parameter/
Return parameter
SYNC
Sets the LIN error type to SYNC.
PARIty
Sets the LIN error type to parity.
CHecksum
Sets the LIN error type to checksum.
Example
:TRIGger:BUS:B1:LIN:ERRTYPE?
>SYNC
:TRIGger:BUS:B1:LIN:ERRTYPE CHECKSUM
:TRIGger:BUS:B1:LIN:ERRTYPE?
>CHECKSUM
Set
Query