Measure:npulse, Measure:pedge – GW Instek GDS-2000A series Programming Manual User Manual

Page 89

Advertising
background image

COMMAND DETAILS

89

:MEASure:NPULSE

Description

Returns the number of negative pulses.

Syntax

:MEASure:NPULSE{?}

Related
Commands

:MEASure:SOURce<X>

Return parameter <NR3>

Returns the number of negative pulses.

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:NPULSE?
4.000E+00
Selects Channel 1, and then measures the number
of negative pulses.

:MEASure:PEDGE

Description

Returns the number of positive edges.

Syntax

:MEASure:PEDGE{?}

Related
Commands

:MEASure:SOURce<X>

Return parameter <NR3>

Returns the number of positive edges.

Chan Off

Indicates the source channel is not
activated.

Query

Query

Advertising