COMMAND DETAILS
131
Related
commands
:TRIGger:TYPe
Parameter
FIELD1
Trigger on field 1
FIELD2
Trigger on field 2
ALLFields
Trigger on all fields
ALLLines
Trigger on all lines
Return parameter
Returns the video trigger field.
Example
:TRIGger:VIDeo:FIELd ALLFields
Sets the video trigger to trigger on all fields.
:TRIGger:VIDeo:LINe
Description
Sets or queries the video trigger line.
Syntax
:TRIGger:VIDeo:LINe {<NR1> | ?}
Related
commands
:TRIGger:TYPe
Parameter
<NR1>
Video line
Return parameter <NR3>
Returns the video trigger line.
Example
:TRIGger:VIDeo:LINe 1
Sets the video trigger to line 1.
:TRIGger:VIDeo:POLarity
Description
Sets or queries the video trigger polarity.
Syntax
:TRIGger:VIDeo:POLarity { POSitive | NEGative | ? }
Related
commands
:TRIGger:TYPe
Parameter
POSitive
Positive polarity
NEGative
Negative polarity
Return parameter
Returns the video trigger polarity.
Set
Query
Set