Before you start, Connecting usb port – 2N Lift8 v1.0 User Manual

Page 23

Advertising
background image

23

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Reset equipment

– press button quickly.

Restoration of factory settings

– press button and hold until all the LEDs

light up red. Then release and wait until SYSTEM LED flashes yellow. Now press

button quickly. All the user settings will now be deleted.

Zeroing the counter of backup rechargeable battery life

– press button

and hold until all the LEDs light up red. Then release and wait until
POWER/BATTERY LED flashes yellow. Now press button quickly. Only perform this
function after replacing the backup rechargeable batteries with new ones!

Configuration of system completeness

– press button and hold until all the

LEDs light up red. Then release and wait until INTERNAL BUS LED flashes yellow.
Now press button quickly. From this moment the system will supervise whether
all the installed equipment (splitters, announcers etc.) are connected and

functional.

Complete deletion of central unit's software

– press button and hold until

all the LEDs light up red. Then release and wait until SYSTEM LED flashes red.
Now press button quickly. NOTA BENE, after performing this function it is only

possible to restore the equipment's normal function using a PC!

Connecting USB port

Recommendation:

Unless necessary do not leave connected to a computer long term. This will
reduce the risk of damage to the computer in the case of a voltage surge from
the telephone line, for example during a storm

Before you start

Conditions for installation of CU:

The central unit (referred to hereinafter as CU) is not intended for outdoor

use.
Do not install the CU on a machine or construction which is a source of
vibrations.
In order to ensure sufficient cooling free access to air must be ensured for the CU
must (it is forbidden to cover the CU, for example with a rag, or to install it in
another enclosed box).
Installation in the lift switchbox is possible if the air temperature in the this box
does not exceed the permitted limits. Remember that a higher air temperature
reduces the lifespan of backup rechargeable batteries in the CU.
It is recommended that the CU be operated in the upright position with the cable
openings at the bottom. Such a mounting makes it possible to ensure the lowest
temperatures of the rechargeable batteries and thus their longest life. Horizontal
mounting is also possible. The upright position with the cable openings at the

top (upside down) is forbidden!
After mounting the CU check that the equipment is firmly fixed in place and that
it cannot come loose and drop down the shaft.

Warning

Do not open the CU

during the warranty period .

After the warranty period open it only to change the rechargeable
batteries.