2N Lift8 v1.0 User Manual

Page 65

Advertising
background image

65

2N TELEKOMUNIKACE a.s., www.2n.cz

®

913

Time limit of
login

10 – 1000 s

60 s

Max. period during which
the control centre worker
must pick up the call and
send a confirmation,
otherwise L8 hangs up and
continues with dialling of
next number. Counted
from the end of dialling.

914

Delayed call

0 – 1000 s

0 s

Used only with connected
entry CANCEL on
announcer in cabin

915

Max. period
TRIPHONY

10 – 9999 s

7200 s

917

Time of
hanging up
between calls

500 – 9999 ms

5000 ms

918

Max. period of
telephone line
test

1 – 20s

5 s

Test of line (the dialling
tone is tested) is
performed each 11
minutes. If no dialling tone
is present three times in a
row, the lift is blocked. As
soon as the line is in
operation again, the lift is
unblocked automatically.

940

Min. period of
dialling tone

200 – 2000 ms

400 ms

The tone must be longer
than a half-period of busy
tone!

941

Min. period of
constant tone

200 – 9999 ms

2000 ms

If the tone lasts long, LN
hangs up.

942

Min. period of
busy tone

100 – 500 ms

200 ms

These parameters can
correct the detection of
the busy tone.

944

Max. difference
of tone – gap

10 – 400 ms

50 ms

945

Min. number
period of busy
tone

2 - 50

5

948

Min. period of
dialling tone

50 – 2000 ms

200 ms

Period of dialling tone is
the length of the section
just before the long gap

949

Min. period of
long gap of
dialling tone
(ring-back)

100 – 5000 ms

2500 ms

The longest gap in the
period of ringing must be
in an interval between the
parameters 949 and 950.

950

Max. period of
long gap of
dialling tone
(ring-back)

500 – 9999 ms

5500 ms

The longest gap in the
period of ringing must be
in an interval between the
parameters 949 and 950.

951

Min. period of
dialling tone

50 – 2000 ms

200 ms

Detection of incoming
call:

The period of the dialling

Advertising