tone is considered to be
the sum of sections
between which there is no
long gap. The longest gap
in the period of ringing
must be in an interval
between the parameters
952 and 953.

NOTA BENE! parameters
951 - 3 function (defaults)
for incoming ringing.

952

Min. period of
long gap of
dialling tone

100 – 5000 ms

1000 ms

953

Max. period of
long gap of
dialling tone

500 – 9999 ms

6000 ms

961

Max. time to
press next
numeral

15 – 120 s

60 s

Counted from the
transition to the new state
(NOT after end of
announcement)

962

Min. period of
pressing of
ALARM button
of announcer in
the cabin

10 – 9999 ms

100 ms

A short value is configured
due to comfortable testing
of the product

968

Period of
ringing to
machine room
(siren)

1 – 60 s

1 s

969

Time of ringing
to intercom

1 – 60 s

1 s

973

Language for
numerical
announcements

0 - 1

1

0 = recorded by user

1 = language of voice
menu

974

Identification of
lift

max. 16 numerals 0
- 9

empty

Allows identification of lift
if there is a foreigner in it
for example. If not filled
in, the serial number is
used.

975

Sequence of
announcements
to cabin
(Alarm)

max. 8
announcements in
a row

empty
(=22)

It allows playing back
messages in more
languages in the defined
sequence, including the
identification number, etc.

01 = User message #1
02 = User message #2
03 = User message #3
04 = User message #4
05 = User message #5
06 = User message #6